<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<title>BTL Inc.</title>
<meta name="keywords" content="Inspection、certification" />
<meta name="description" content="BTL electronic product testing and certification, providing electronic product certification services in many regions at home and abroad.  " />
<meta name="viewport" content="width=1100,target-densitydpi=high-dpi,user-scalable=yes"/>
<link rel="stylesheet" type="text/css" href="../css/css.css">
<link rel="stylesheet" type="text/css" href="../css/banner.css">
<link rel="stylesheet" type="text/css" href="../css/animate.min.css">
<script language="JavaScript" type="text/JavaScript" src="../js/jquery-1.7.1.min.js"></script>
<script language="JavaScript" type="text/javascript" src="../js/banner.js"></script>
<script language="JavaScript" type="text/JavaScript" src="../js/images.js"></script>
<script language="JavaScript" type="text/JavaScript" src="../js/clearbox.js"></script>
<script language="JavaScript" type="text/JavaScript" src="../js/wow.min.js"></script> 
<script>
function uaredirect(f){
	try{
		var b=false;
		if(arguments[1]){
			var e=window.location.host;var a=window.location.href;
			if(isSubdomain(arguments[1],e)==1){
				f=f+"/#m/"+a;b=true
			}else{
				if(isSubdomain(arguments[1],e)==2){
					f=f+"/#m/"+a;b=true
				}else{
					f=a;b=false
				}
			}
		}else{
			b=true
		}
		if(b){
			var c=window.location.hash;
			if(!c.match("fromapp")){
				if((navigator.userAgent.match(/(iPhone|iPod|Android|ios|iPad)/i))){
					location.replace(f)
				}
			}
		}
	}catch(d){}
}
uaredirect('../men/industryshow.php?id=709');

wow = new WOW({animateClass: 'animated',offset:100}); 
wow.init();
$(document).ready(function(){
  $(".menu li").hover(function(){
  	$("div",this).fadeIn();
  },function(){
  	$("div",this).fadeOut();
  });
  $(".menu2 ul li").hover(function(){
  	$("div",this).fadeIn();
  },function(){
  	$("div",this).fadeOut();
  });
  $(".menu li div h6").hover(function(){
  	$("dl",this).fadeIn();
  },function(){
  	$("dl",this).fadeOut();
  });
});
</script>
</head>
<body>
<div class="toper">
	<div class="topcen">
    <form name="topform" method="post" action="serach.php">
    	<input type="text" name="topword" value="" class="topinp" />
        <input type="submit" name="topsub" value="" class="topsub" />
    </form>
	<span class="language"><a href="../cn/index.php">简</a> | <a href="../index.php">繁</a> | <a href="index.php" >EN</a></span>
	<div class="fl logoer"><a href="index.php" ><img src="../images/logo.png"></a><p>Stock Code: 6840</p></div>
    <ul class="menu">
		<li><a href="index.php">Home</a></li>
        <li><a href="group.php" class="m">About BTL</a>
    	<div>
        	<a href=group.php?cid=486>Group profile</a><a href=group.php?cid=487>Group news</a><a href=group.php?cid=489>Complaints process</a><a href=group.php?cid=498>Reporting channels for violations of professional ethics</a><a href=group.php?cid=491>Certificate</a><a href=group.php?cid=488>Declaration of impartiality</a>        </div>
    </li>
        <li><a href="industry.php" class="m">Technical platform</a>
    	<div>
        	<a href=industry.php?cid=473>Mobile Communication</a><a href=industry.php?cid=479>BQB</a><a href=industry.php?cid=472>SAR / OTA</a><a href=industry.php?cid=480>IoT</a><a href=industry.php?cid=413>EMC</a><a href=industry.php?cid=424>RF</a><a href=industry.php?cid=474>Telecom</a><a href=industry.php?cid=425>Safety</a><a href=industry.php?cid=494>New Energy</a><a href=industry.php?cid=481>Other</a><a href=industry.php?cid=504>Information security</a>        </div>
    </li>
        <li><a href="Global.php" class="m">Global market access</a>
    	<div>
        	<h6><a href=Global.php?cid=416>East Asia & South Asia</a><dl><dd><a href=news.php?cid=440>China</a></dd><dd><a href=news.php?cid=456>Japan</a></dd><dd><a href=news.php?cid=458>Indian</a></dd><dd><a href=news.php?cid=459>Korea</a></dd><dd><a href=news.php?cid=460>Taiwan</a></dd></dl></h6><h6><a href=Global.php?cid=417>Southeast Asia</a><dl><dd><a href=news.php?cid=433>Indonesia</a></dd><dd><a href=news.php?cid=434>Malaysia</a></dd><dd><a href=news.php?cid=435>Thailand</a></dd><dd><a href=news.php?cid=436>Vietnam</a></dd></dl></h6><h6><a href=Global.php?cid=418>Middle East</a><dl><dd><a href=news.php?cid=461>Saudi Arabia</a></dd></dl></h6><h6><a href=Global.php?cid=419>Africa</a><dl><dd><a href=news.php?cid=463>South Africa</a></dd></dl></h6><h6><a href=Global.php?cid=420>Europe</a><dl><dd><a href=news.php?cid=465>European Union</a></dd><dd><a href=news.php?cid=492>United Kingdom</a></dd><dd><a href=news.php?cid=464>Russia</a></dd></dl></h6><h6><a href=Global.php?cid=421>South America</a><dl><dd><a href=news.php?cid=469>Argentina</a></dd><dd><a href=news.php?cid=470>Brazil</a></dd></dl></h6><h6><a href=Global.php?cid=422>North America</a><dl><dd><a href=news.php?cid=466>USA</a></dd><dd><a href=news.php?cid=467>Canada</a></dd><dd><a href=news.php?cid=468>Mexico</a></dd></dl></h6>        </div>
    </li>
        <li><a href="Investor.php" class="m">Investors zone</a>
    	<div>
        	<a href=Investor.php?cid=484>Croporate Governance</a><a href=Investor.php?cid=485>Stakeholder Zone</a><a href=Investor.php?cid=501></a><a href=Investor.php?cid=426>Financial and Business Information </a><a href=Investor.php?cid=482>Stock Quote and Dividend History</a><a href=Investor.php?cid=427>Shareholders's Service</a><a href=Investor.php?cid=490>Investor conference</a><a href=Investor.php?cid=483>Stock Affairs </a><a href=Investor.php?cid=502>Information Security</a>        </div>
    </li>
        <li><a href="join.php" class="m">HR Section</a>
    	<div>
        	<a href=join.php?cid=428>Talent recruitment</a><a href=join.php?cid=503>Human Rights Policy</a><a href=join.php?cid=499></a><a href=join.php?cid=500></a><a href=contact.php>Contact Us</a>        </div>
    </li>
        
    </ul>
    </div>
</div>
<div class="bgw">

<div class="m2pos">
 <div class="main"><span class="m2posNm">Location：<a href='index.php'>Home</a> - Technical platform - AI Data Center EMC Perspectives</span></div>
 </div>
 <div class="p50">



 
 <div class="m2proBox" style="border-bottom:0;">
<div class="main clear"><div class="lyleft">
    	<ul>
		<li><a href=industry.php?cid=473 class=>Mobile Communication</a></li><li><a href=industry.php?cid=479 class=>BQB</a></li><li><a href=industry.php?cid=472 class=>SAR / OTA</a></li><li><a href=industry.php?cid=480 class=>IoT</a></li><li><a href=industry.php?cid=413 class=cur>EMC</a></li><li><a href=industry.php?cid=424 class=>RF</a></li><li><a href=industry.php?cid=474 class=>Telecom</a></li><li><a href=industry.php?cid=425 class=>Safety</a></li><li><a href=industry.php?cid=494 class=>New Energy</a></li><li><a href=industry.php?cid=481 class=>Other</a></li><li><a href=industry.php?cid=504 class=>Information security</a></li>        </ul>
    </div>
    <div class="lyright">
<div class="pp2">
<div class="tt">AI Data Center EMC Perspectives</div>
<div class="txt2 txtimg"><p><span style="background-color: rgb(255, 0, 0); color: rgb(255, 255, 255);"><strong>1. Introduction&nbsp;</strong></span></p><p>Currently, there is no dedicated international product standard specifically governing EMC testing for AI data centers. Instead, verification procedures still rely on familiar frameworks such as CISPR 32, CISPR 35, and harmonic requirements. However, the unique characteristics of AI data centers present new challenges: high-power three-phase electrical systems, ultra-high-speed and high-volume data streaming, advanced thermal dissipation technologies, substantial system loading, and complex power distribution architectures. The frequency spectrum involved spans from low-frequency control of three-phase power stability to coupling effects and high-frequency scattering induced by ultra-fast data transmission. These factors collectively pose significant tests and challenges to EMC validation in this emerging domain.</p><p><br/></p><p><span style="color: rgb(255, 255, 255); background-color: rgb(255, 0, 0);"><strong>2. Perspective and Considerations&nbsp;</strong></span></p><p><strong><span style="color: rgb(255, 0, 0);">2.1 Three-Phase Power PSU Rack</span></strong></p><p><strong>(1) The IEC 61000-3-12 standard, applicable to equipment drawing more than 16A per phase, specifies harmonic current limits for three-phase systems. Depending on the product’s operational characteristics, compliance testing can be conducted using Table 3 through Table 5 of the standard. This section provides an analysis of the differences among these tables and offers guidance on how to select the appropriate test criteria based on product behavior and system configuration.</strong></p><p><img src="/upload_files/2025-11/1763531219140916.jpg" title="1763531219140916.jpg" alt="1763531219140916.jpg" width="800" height="422"/></p><p><strong>(1.1) Practical Implementation Considerations</strong></p><ul class=" list-paddingleft-2" style="margin-top: 12px; margin-bottom: 12px; width: 1147.6px; padding: 0px; -webkit-tap-highlight-color: rgba(0, 0, 0, 0); box-sizing: border-box; list-style-position: initial; list-style-image: initial; margin-block-start: 1em; margin-inline: 0px; font-family: 微软雅黑; font-size: 12px; text-wrap-mode: wrap; background-color: rgb(255, 255, 255);"><li><p><span style="font-family: arial, helvetica, sans-serif; font-size: 16px;">For server products, the ideal approach is to perform testing using Table 3 with Rsce = 33. However, due to the complexity of these products—especially when power exceeds 60 kW—it is often difficult to meet the linearity requirements. If Rsce = 33 cannot be satisfied, alternative values such as 66, 120, or 250 may be considered. In such cases, it is necessary to report the selected Rsce value to the CSP (Certification Service Provider) for approval, and clearly annotate the chosen Rsce in the test report.</span></p></li><li><p><span style="font-family: arial, helvetica, sans-serif; font-size: 16px;">For systems utilizing dual power sources combined into a high-voltage output, or those incorporating CDU (Coolant Distribution Unit) equipment, Table 4 is generally more representative of actual operating conditions. During the development phase, it is essential to measure the relationship between current and voltage phase angles, aiming to meet the angular criteria defined in Table 4. This data supports the CSP in calculating harmonic current superposition and assessing temperature rise in protective switching devices.</span></p></li></ul><p><strong>(1.2) Key Considerations</strong></p><ul class=" list-paddingleft-2" style="margin-top: 12px; margin-bottom: 12px; width: 1147.6px; padding: 0px; -webkit-tap-highlight-color: rgba(0, 0, 0, 0); box-sizing: border-box; list-style-position: initial; list-style-image: initial; margin-block-start: 1em; margin-inline: 0px; font-family: 微软雅黑; font-size: 12px; text-wrap-mode: wrap; background-color: rgb(255, 255, 255);"><li><p><span style="font-family: arial, helvetica, sans-serif; font-size: 16px;">When applying Table 4, if the phase angle between the fifth harmonic current (I5) and the fundamental voltage is controlled within the range of 90° to 150°, the product input tends to exhibit capacitive characteristics. Under such conditions, transient current levels may increase significantly. Therefore, it is recommended to incorporate filters operating above 150 kHz to mitigate potential EMC risks and ensure system stability.</span></p></li></ul><p><strong>(1.3) Recommended EMC Verification Procedure (for Servers or PSUs Above 60 kW)</strong></p><ul class=" list-paddingleft-2" style="margin-top: 12px; margin-bottom: 12px; width: 1147.6px; padding: 0px; -webkit-tap-highlight-color: rgba(0, 0, 0, 0); box-sizing: border-box; list-style-position: initial; list-style-image: initial; margin-block-start: 1em; margin-inline: 0px; font-family: 微软雅黑; font-size: 12px; text-wrap-mode: wrap; background-color: rgb(255, 255, 255);"><li><p><span style="font-family: arial, helvetica, sans-serif; font-size: 16px;">a. Configure Table 4 with Rsce = 33. After a 10-minute warm-up period, begin testing for 20 minutes. Perform measurements at 10%, 20%, 50%, and 100% load levels. Examine the phase angle between the fifth harmonic current (I5) and the fundamental voltage to determine whether it falls within the 90°–150° range or varies randomly across 0°–360°. Record all observations and proceed to step b.</span></p></li><li><p><span style="font-family: arial, helvetica, sans-serif; font-size: 16px;">b. If the measured angles fall within the criteria defined in step a, initiate a second formal test using Table 4 with Rsce = 33. If the test passes, the verification is complete. If the test fails to meet the limit criteria, proceed to step c.</span></p></li><li><p><span style="font-family: arial, helvetica, sans-serif; font-size: 16px;">c. Reconfigure the test using Table 4 with Rsce = 250 and conduct a third round of testing. If the test passes, the verification is complete.</span></p></li><li><p><span style="font-family: arial, helvetica, sans-serif; font-size: 16px;">d. If the phase angle criteria in step a are not met, proceed to step e.</span></p></li><li><p><span style="font-family: arial, helvetica, sans-serif; font-size: 16px;">e. Switch to Table 3 and determine an appropriate Rsce value based on the results from step b. Consider &nbsp;Rsce values such as 66, 120, 250, or 350, and conduct the test accordingly.</span></p></li></ul><p><img src="/upload_files/2025-11/1763531242404369.jpg" title="1763531242404369.jpg" alt="公式.jpg" width="356" height="104"/></p><p><span style="font-size: 12px;">The Z value typically includes the combined impedance of the transformer, busbar, and cable. (The laboratory cannot determine the Z value in the above formula.) Therefore, the selection of Rsce should be recommended by the CSP. Furthermore, the Rsce value also involves the characteristic parameters of the power supply and circuit breaker.</span></p><p>&nbsp;</p><p><span style="color: rgb(255, 0, 0);"><strong>2.2&nbsp; Potential Oversights in CE (Conducted Emission) Testing for PSUs</strong></span></p><p>Under certain load conditions, a product may exhibit abnormal low-frequency resonance. In such cases, the LISN (Line Impedance Stabilization Network) presents low impedance at low frequencies. If no filter is installed at the LISN input, this resonance may be inadvertently discharged to ground, potentially leading to a false pass in the CE test. However, the root cause of the resonance remains unresolved.</p><p>By inserting a filter between the power source output and the LISN, the instability is no longer masked by the LISN’s low-frequency characteristics. Furthermore, in high-power circuit designs, it is essential to consider the impedance range before and after the product—such as the inclusion of filters—to prevent resonance issues.</p><p>For a detailed discussion of this topic, refer to BTL’s publication:&nbsp;<span style="color: rgb(0, 112, 192);">&#39;</span><a href="https://www.btl.com.tw/en/industryshow.php?id=691" target="_blank">Latent Cognitive Risks in EMC Compliance Testing for AI-Based Power Systems</a><span style="color: rgb(0, 112, 192);">&#39;</span></p><p>&nbsp;</p><p><span style="color: rgb(255, 0, 0);"><strong>2.3&nbsp; IEC 61000-3-11: Voltage Flicker Considerations</strong></span></p><p>&nbsp;The original intent of voltage flicker limits under IEC 61000-3-11 was to regulate power products that could cause flicker disturbances—particularly affecting shared power sources, other connected devices, or lighting systems. However, modern AI systems typically operate within dedicated power zones equipped with their own voltage regulation and protection infrastructure. These systems feature isolated and robust power management architectures. As such, the applicability of flicker requirements to AI systems is limited and may no longer be relevant under current deployment models.</p><p>&nbsp;</p><p><span style="color: rgb(255, 0, 0);"><strong>2.4&nbsp; Recommendation: Include Handheld Communication Immunity Testing</strong></span></p><p>During operations or inspections within computer rooms or AI Data Centers, personnel often carry handheld radios, mobile phones, or use video recording devices. These wireless communication tools may introduce electromagnetic interference (EMI) to nearby equipment. Therefore, it is advisable to incorporate handheld device immunity testing into the EMC verification process.</p><p>This consideration is especially relevant for environments such as railway system control rooms, where similar testing protocols are already applied. For applicable test methods and regulatory references, ISO 11452-9 provides a suitable framework for evaluating immunity against radiated disturbances from portable transmitters.</p><p><br/></p><p><strong><span style="color: rgb(255, 0, 0);">2.5&nbsp; Recommendation: Adopt EV-Grade Shielded Cables for AI Server PSUs</span></strong></p><p>Currently, external PSU cables used in AI servers often lack multi-layer mesh shielding, which makes them vulnerable to radiated emissions (RE) and complicates system design and stability—particularly in terms of impedance weighting and noise control.</p><p>In contrast, electric vehicles (EVs) have long adopted shielded cable architectures with mature design practices. These cables offer effective electromagnetic shielding, with noise suppression capabilities reaching 40 dB to 60 dB. By adopting similar cable types for AI server PSUs, RE scattering can be significantly reduced, enhancing both EMC performance and overall system robustness.</p><p><br/></p><p><span style="color: rgb(255, 255, 255); background-color: rgb(255, 0, 0);"><strong>3. Conclusion&nbsp;</strong></span></p><p>As the performance demands of AI servers continue to grow, EMC verification must evolve in tandem—requiring holistic, system-wide design alignment and weight-balanced development strategies. Beyond technical compliance, it is equally important to reflect on environmental limitations and continuously refine design practices to enhance product manufacturability, consistency, and stability.</p><p>In this domain, especially for high-power products, there remains significant room for advancement in certification methodologies, as outlined in this paper. Furthermore, cross-disciplinary integration and mutual learning between fields should be actively encouraged to foster innovation and resilience across the ecosystem.</p></div>
</div>


</div>

<div style="float:right"><a href="industry.php"><img src=images/back.gif border=0></a><a href=#><img src=images/top_x.gif border=0></a></div>

</div>

</div>

 </div>




</div>
<div class="bommenu">
	<ul>
        <li><a href="group.php">About BTL</a>
    	<div>
        	<a href=group.php?cid=486>Group profile</a><a href=group.php?cid=487>Group news</a><a href=group.php?cid=489>Complaints process</a><a href=group.php?cid=498>Reporting channels for violations of professional ethics</a><a href=group.php?cid=491>Certificate</a><a href=group.php?cid=488>Declaration of impartiality</a>        </div>
    </li>
        <li><a href="industry.php">Technical platform</a>
    	<div>
        	<a href=industry.php?cid=473>Mobile Communication</a><a href=industry.php?cid=479>BQB</a><a href=industry.php?cid=472>SAR / OTA</a><a href=industry.php?cid=480>IoT</a><a href=industry.php?cid=413>EMC</a><a href=industry.php?cid=424>RF</a><a href=industry.php?cid=474>Telecom</a><a href=industry.php?cid=425>Safety</a><a href=industry.php?cid=494>New Energy</a><a href=industry.php?cid=481>Other</a><a href=industry.php?cid=504>Information security</a>        </div>
    </li>
        <li><a href="Global.php">Global market access</a>
    	<div>
        	<a href=Global.php?cid=416>East Asia & South Asia</a><a href=Global.php?cid=417>Southeast Asia</a><a href=Global.php?cid=418>Middle East</a><a href=Global.php?cid=419>Africa</a><a href=Global.php?cid=420>Europe</a><a href=Global.php?cid=421>South America</a><a href=Global.php?cid=422>North America</a>        </div>
    </li>
        <li><a href="Investor.php">Investors zone</a>
    	<div>
        	<a href=Investor.php?cid=484>Croporate Governance</a><a href=Investor.php?cid=485>Stakeholder Zone</a><a href=Investor.php?cid=501></a><a href=Investor.php?cid=426>Financial and Business Information </a><a href=Investor.php?cid=482>Stock Quote and Dividend History</a><a href=Investor.php?cid=427>Shareholders's Service</a><a href=Investor.php?cid=490>Investor conference</a><a href=Investor.php?cid=483>Stock Affairs </a><a href=Investor.php?cid=502>Information Security</a>        </div>
    </li>
        <li><a href="join.php">HR Section</a>
    	<div>
        	<a href=join.php?cid=428>Talent recruitment</a><a href=join.php?cid=503>Human Rights Policy</a><a href=join.php?cid=499></a><a href=join.php?cid=500></a><a href=contact.php>Contact Us</a>        </div>
    </li>
        </ul>
</div>
<div class="end">
	<p><strong>LINK: </strong>
	<a href=https://www.globalcertificationforum.org/ target=_blank>GCF</a><a href=https://www.ptcrb.com/ target=_blank>PTCRB</a></p>
Copyright © 2008-2019 BTL Inc.  All Rights Reserved  ICP NO.18145055<a href="https://beian.miit.gov.cn" target="_blank">粤ICP备18145055号</a>&nbsp;&nbsp;技术支持：<a href="http://www.0769net.com/" target="_blank">东莞网页设计</a>
</div>
</body>
</html>