1.

Q:Which(s) of the standard should be followed for the 30-960MHz standalone receiver product? Standard RSS-Gen or ICES-003?

A:The regulations of RSS-Gen clearly specified that the standard-alone receiver products working in the range of 30-960mhz should comply with the regulations of chapter 7, so RSS-Gen is a must.

      For ICES-003 refers to the following three situations:

      a. If there is no ITE function with the product, this product is out of the scope of ICES-003, so ICES-003 is not applied;

      b. ITE function of the product is only used to assist the operation of wireless function, and it does not control other functions or performance, this product is still out of the scope of ICES-003, so ICES-003 is not applied;

     c. ITE function controls other functions or performance other than wireless function, which falls within the scope of ICES-003, thus ICES-003 must be followed.


2.

Q:Is CAB recognition already mandatory for testing laboratories by ISED?

A:Yes, it is already mandatory. The mandatory date is 2019/3/15 with the transition period 3 months. 

      BTL Dongguan Lab was recognized by ISED in February 2019 with CAB number CN0042.


3.

Q:If the product is used within 20cm of the human body, is SAR testing required?

A:For the products used within 20cm of the human body, it shall be determined by the actual use distance, output power and working frequency of the product that if SAR testing is need to be done or not.

      The judgment can be made according to the following table of ISED standard RSS-102 Issue 5:

Canada.png

Relevant information

Canada ISED Update No.2 | RSS Gen Issue 6: Analysis of General Compliance Standards for Radio Frequency Equipment
2026-08-21

Canada ISED Update No.2 | RSS Gen Issue 6: Analysis of General Compliance Standards for Radio Frequency Equipment

Last week, we mentioned that Innovation, Science and Economic Development Canada (ISED) released RSS 310 Issue 6: Licence Exempt Radio Frequency Devices...

CRA Implementation Enters a Critical Phase
2026-08-21

CRA Implementation Enters a Critical Phase

In August 2026, preparations for the implementation of the EU Cyber Resilience Act (CRA) entered a critical stage. With the reporting obligations set to take effect on September 11, 2026, drawing near, the European Commission and the European Union Agency for Cybersecurity (ENISA) have been intensively issuing implementation guidance and materials related to the single reporting platform.

Canada's ISED Officially Releases RSS-310 Issue 6: Major Updates to Radio Frequency Equipment Requirements
2026-08-03

Canada's ISED Officially Releases RSS-310 Issue 6: Major Updates to Radio Frequency Equipment Requirements

Innovation, Science and Economic Development Canada (ISED) has formally issued RSS-310, Issue 6, “Licence-Exempt Radio Apparatus: Category II Equipment,” replacing Issue 5, which has been in effect since 2020

Privacy Preference Center

We use cookies to allow our website to function properly, personalize content and advertisements, provide social media features, and analyze traffic. We also share information about your use of our website with our social media, advertising, and analytics partners.

View Privacy Policy

Manage consent settings

Necessary Cookies

Uniformly activate

The operation of the website relies on these cookies, and you cannot disable them in the system. These cookies are typically set based on your actions (i.e., service requests), such as setting privacy preferences, logging in, or filling out forms. You can configure your browser to block or prompt you about these cookies, but this may cause certain website functionalities to not work.

Select Language