August 1, 2024 onwards, lithium battery CCC certification has been mandatory, meaning that lithium-ion batteries or action power supply in the domestic factory, sales, imports and other activities need to obtain the 3C certification in order to legally sell, 3C certification applies not only to companies with domestic, but also applies to foreign imports into the domestic customer companies, the current e-commerce platforms have been asked to action power supply products need to provide the 3C certification in order to be shelved on the platform for sale, the Has your product obtained CCC certification? The following is a compilation of the scope of the application for 3C certification and 3C certification FAQs to share


The scope of certified products see the table below:

1723011130138282.jpg


The following is a compilation of recent FAQs about 3C certification of lithium batteries.


1. Does the headphone charging case, whose internal battery cell has a rated capacity of no more than 600mAh, require CCC certification?

The charging case is not greater than 600mAh does not need to follow the mobile power CCC certification, but the charging case internal battery cell / battery pack, need to carry out CCC certification.


2. Headphone charging cases with internal cells rated at greater than 600mAh, must headphones be included in the inventory control? CCC certification?

A. The charging case needs to be CCC certified according to the mobile power supply.

B. The internal battery cell/battery pack of the charging case needs to be CCC certified.

C.If companies want to include headphones in the list of charging boxes, for headphones included in the same certification unit, they should also be internal lithium battery/group for CCC certification, and headphones for GB4943.1 sound pressure test.


3. May I ask the mobile power component battery is a certified battery pack (battery pack with certification), whether it is still necessary to carry out GB31241-2022 test?

The whole mobile power supply is no longer tested by GB 31241, but only by GB 4943.1.


4. May I ask, if the product and the cell are both CCC certified, but because the battery pack has been assembled into a semi-finished product, the 3C marking cannot be applied to the cell alone, how do we deal with this part? 3C marking on the cell unit, how do we deal with this part?

After obtaining the CCC certificate, the battery cell to be sold in the factory must be marked with CCC for the battery cell. However, before obtaining the CCC certificate But before the CCC certificate, the electric core has been sold in the factory, can not be marked.


5. The battery cells are self-produced and sold for random testing of battery packs, and the battery packs are marked with CCC Logo after being awarded CCC. Is it necessary to mark the part of the battery cell with CCC?

The batteries are randomly tested and do not have CCC certificate, so they can not be marked with CCC Logo. 2024.8.1 onwards, batteries After 2024.8.1, the battery cell needs to do CCC and hit CCC Logo.


6. What kind of organisational structure of a manufacturing business relationship can satisfy the conditions for self-production and self-sales? Head office or sub-parent company?

It is generally accepted that the situation where the enterprise produces its own products for reprocessing production in the next segment (the products are sold to itself) satisfies the condition of self-production and self-sales. sells to itself), satisfies the condition of self-production and self-sale. The head office and branch office belong to the same legal person and satisfy the condition of self-production and self-sale; the subsidiary and parent company A parent company does not belong to the same legal person and does not satisfy the condition of self-manufacturing and self-selling.


7.Should lithium-ion batteries for medical devices (e.g., internal batteries for blood pressure monitors and blood glucose monitors) be subject to CCC certification in accordance with GB 31241-2022?

Lithium-ion batteries and battery packs for medical devices are not within the scope of GB 31241 standard and do not need to apply for CCC.


8. Does car emergency starting power belong to mobile power?

The car emergency starting power supply itself is not a mobile power supply, but when the car emergency starting power supply contains a similar USB output port that However, when the car emergency starting power supply contains similar USB output port, which can charge other information technology devices and has the function of mobile power supply, it can be assessed only for the function of mobile power supply in the CCC catalogue. power supply function, and expressly state on the certificate that "only the mobile power supply function is assessed".


9.Our company sells the whole product, in order to adapt to the market demand for a variety of products for the whole product affixed with a number of brands or change a number of Model, but the actual machine products have not changed. In this case, our company is only required to apply for a CCC certification? Or each brand, Each model should apply for individual CCC certification?

If the unit division requirements are met, multiple models of products can be applied for CCC according to a unit; multiple brands need to apply for CCC separately. Separate application for CCC.


10.Regarding the second point on the division of battery pack cells, the component cells are of the same type, does "of the same type" mean that they must be of the same chemical composition or that it is sufficient if the soft/hard case is the same? Does the same type mean that the cells must be of the same chemical composition, or does it mean that as long as the soft pack/hard case is the same, it is OK? Or the CELL type must be the same?

Type here means: cylindrical, soft pack, hard case, etc. However, the chemical composition of the batteries is the same, so that they can be matched to form a battery pack. the same chemical composition to form a battery pack.


Battery 3C certification application requires the following information:

(1) Application for certification;

(2) Product specification

(3) List of safety critical parts, working parameters, battery nameplate, battery pack nameplate, internal section of the battery, battery pack circuit diagrams and layout drawings

(4) Business licence of the manufacturer

(5) Battery, battery pack specifications, Chinese nameplate

(6) Test samples


Number of samples to be sent:

a. Batteries send samples of 24 (can send more than 6 spare samples);

b. Battery packs to send a sample of 37 (can send more than 3 spare samples).

c. The number of samples of action power supply is at least 12 units.


BTL New Energy Division focuses on consumer batteries, power batteries, energy storage battery product certification field for many years, has a perfect battery, power batteries, energy storage battery product testing and certification capabilities, now can provide customers around the world to provide a global scope of certification, commissioned testing services, to help customers enter the global market battery products smoothly one-stop service.


Relevant information

EU Releases Exemption Guidelines on Removability and Replaceability of Portable and LMT Batteries — Multiple Product Categories Relief Granted
2026-08-04

EU Releases Exemption Guidelines on Removability and Replaceability of Portable and LMT Batteries — Multiple Product Categories Relief Granted

On July 14, 2026, the European Commission published the "Commission Guidelines to Facilitate the Harmonised Application of Provisions on the Removability and Replaceability of Portable and Light Means of Transport (LMT) Batteries" (Commission Notice C(2026) 5032 final). These guidelines aim to provide a uniform interpretative framework for the implementation of Article 11 of the EU Battery Regulat

6G Developments: Past, Present and Future
2026-07-28

6G Developments: Past, Present and Future

The formulation of 6G standards has entered a more concrete phase. At the 3GPP RAN Plenary Meeting held in Singapore in June 2026, the industry made progress in multiple key research areas and finalized the timeline for Release 21, which is regarded as the first standard version expected to formally define 6G.

Overview of EN IEC 61000-4-29:2026
2026-07-03

Overview of EN IEC 61000-4-29:2026

The key focus of the 2026 edition is to address new DC power distribution environments, especially higher-voltage DC systems. It also clarifies test generator capability, duration tolerance, current limitation during short interruptions, inrush current verification, result evaluation, and test report requirements. For products using 24 Vdc, 48 Vdc, 380 Vdc, 400 Vdc, 800 Vdc, or other DC input pow

Privacy Preference Center

We use cookies to allow our website to function properly, personalize content and advertisements, provide social media features, and analyze traffic. We also share information about your use of our website with our social media, advertising, and analytics partners.

View Privacy Policy

Manage consent settings

Necessary Cookies

Uniformly activate

The operation of the website relies on these cookies, and you cannot disable them in the system. These cookies are typically set based on your actions (i.e., service requests), such as setting privacy preferences, logging in, or filling out forms. You can configure your browser to block or prompt you about these cookies, but this may cause certain website functionalities to not work.

Select Language